What the Job Includes

A gas log set still makes heat and exhaust, so the fireplace beneath it has to be sound. We check the firebox, flue and existing gas stub before recommending a set, then match burner width and heat output to the opening. Vented sets need the flue held open for good, and we fit the stop that does it. Sold a set by a showroom that never saw the fireplace? We make sure it suits before it is lit.

Firebox and flue judged sound before any set
Burner width matched to the opening
Gas stub pressure-tested for leaks
Fixed damper stop fitted on vented sets
Match, remote or wall switch controls
Showroom sets checked for fit before lighting

The Decisions Hidden in a Gas Log Quote

A gas log quote looks simple, logs and a burner and an afternoon's work, and it hides the decisions that matter. The first is type. The sets we fit in Westminster fireplaces are vented sets: they burn with a tall, loose, yellow flame much like a wood fire, they make exhaust and a little soot to go with it, and so they need a working flue above them and a damper fixed so that it cannot be shut while the burner is on. They are fires for looking at more than for heating, since much of the warmth leaves with the exhaust, and anyone who tells you otherwise is selling. Unvented sets, sold elsewhere to heat a room with no flue at all, are a separate product that California restricts, and a quote proposing one here deserves a careful second look. The second decision is control: a manual valve lit with a match, a standing safety pilot, or a remote system. Each costs more than the last and each changes what has to sit in the firebox.

Size is where quotes most often miss. A log set has to fit the firebox with air around it, and fireboxes taper, so the width at the back wall governs, not the width of the opening you see from the sofa. We take the four dimensions the makers ask for, plus the position of the gas stub, and choose from the sets that fit with the clearances their instructions demand. A set bought online by front width alone and then crammed against the side walls overheats the valve and scorches the brick, and we are asked to sort out a few of those every year. The gas supply matters as much. The line into the firebox has to deliver enough for the burner's rating, and an old stub sized for a log lighter may not. We check the pressure and the shutoff, and we say so if a plumber needs to upsize the line before any logs go in.

Flue First, Then the Price

Because a vented set relies on the chimney, the chimney is looked at before the set is ordered. A flue that served wood fires for decades may be coated, cracked or blocked, and gas exhaust is wetter and cooler than wood smoke, which is hard on old clay and old mortar. If the fireplace has been in regular use and nothing else is changing, the $175 Level 1 inspection is the fitting check. If the house has just changed hands or the flue's history is unknown, the $415 Level 2 with the camera is the careful one, and a sweep priced from $445 may be needed so the camera can see. Skipping this step is the most common shortcut in gas log quotes. It is also the one a buyer's inspector will catch later, when soot streaks appear above the opening and somebody asks what the logs are venting into.

Log sets have no list price on this site. Our figure is written up after you have picked a set and a control type and we have measured, and it covers the burner, logs, embers and media, the valve or pilot kit, the damper stop, connection to the existing stub and a leak test of every joint we make. Work on the gas line upstream of the firebox is listed separately if it is needed. On the day, the firebox is cleaned, the burner is set and leveled, and the logs are placed strictly by the maker's diagram, because flame touching a log in the wrong place is what makes soot. We light it, let it reach temperature and check the flame with you. You keep the manual and the model details. Should you want real heat from this fireplace later, the other route is a gas insert behind glass, which costs $2,950 to $5,950 fitted.

How Mulberry Chimney Pros Handles This Job

Camera Before Quote

The flue is filmed before any price is written

Three Clear Piles

Fix now, plan for later, or leave alone

Written Scope

Price and work list on paper before we start

Your Quote Welcome

Bring another estimate and we check it line by line

More Inspections and Repairs

Chimney Sweep

Flue, smoke chamber and firebox brushed clean, with before and after camera stills so you can see what the soot was hiding.

Read more →

Chimney Inspection

A Level 1 check of the reachable firebox, damper, flue and chimney top, reported as photos with a plain verdict on each.

Read more →

Chimney Repair

Chimney repairs priced line by line, each tied to a photo of the defect, so you can tell needed work from padding.

Read more →

Fireplace Inspection

The firebox, hearth, surround and damper examined at arm's length, with photos showing which cracks and gaps matter and which are cosmetic.

Read more →

Fireplace Repair

Firebrick, refractory panels, dampers and hearths repaired, limited to the parts photos show have failed.

Read more →

Chimney Level 2 Inspection

A camera inspection of the entire flue interior plus the accessible spaces around the chimney, delivered as footage and a ranked findings list.

Read more →

Chimney Cap Installation

New chimney caps measured at the flue and fastened down, replacing rusted, missing or wrong-size covers that let weather and animals in.

Read more →

Chimney Flashing Repair

Step and counter flashing where the stack meets the shingles resealed or replaced, after a water test shows where the leak begins.

Read more →

Chimney Masonry Repair

Eroded mortar joints repointed and damaged brick swapped out, with the affected courses marked on photos before work is priced.

Read more →

Chimney Rebuilds

Partial or full chimney rebuilds, recommended only when photos and measurements show the existing stack cannot be repaired.

Read more →

Fireplace Cleaning

Firebox walls, grate, glass doors and the facing above the opening cleaned of ash and smoke film, then photographed bare.

Read more →

Gas Fireplace Cleaning

Glass, burner ports, pilot hood and log set cleaned on gas fireplaces, with flame and venting checked before the front goes back on.

Read more →

Gas Fireplace Repair

Gas fireplaces that refuse to light, drop out mid-burn or ignore the remote diagnosed with a meter and repaired part by part.

Read more →

Fireplace Remodel

Fireplace facings, mantels and hearths rebuilt in new materials, with clearances to anything that burns verified before the design is fixed.

Read more →

Fireplace Inserts

Wood, pellet and gas inserts chosen to fit the existing firebox and vented with their own liner, once the chimney passes a camera check.

Read more →

Pellet Stove Repair

Motors, igniter, sensors and vent tested one at a time on a misbehaving pellet stove, so only the failed component gets replaced.

Read more →

Wood Stove Repair

Door seals, firebrick, baffles, glass and stovepipe replaced on wood stoves, after a check that the stove body merits the repair.

Read more →

Chimney Seismic Retrofit

Unreinforced brick chimneys assessed for earthquake risk, then braced, strapped or rebuilt lighter above the roof as the findings direct.

Read more →

Chimney Crown Repair

The cement wash that sheds rain off the chimney top resurfaced or recast, depending on what close-up roof photos show.

Read more →

Dryer Vent Cleaning

Lint cleared from the full dryer duct, wall connection to outside hood, with airflow measured before and after.

Read more →

Chimney Liner Installation

Stainless steel liners installed in flues where camera footage shows cracked, missing or wrong-size clay tile.

Read more →

Chimney Leak Repair

Water entry at the chimney tracked to its tested source, then fixed at that point instead of sealing everything in sight.

Read more →

Chimney Waterproofing

Penetrating repellent sprayed on brick and mortar that absorb rain, applied only after a spray test and any needed repairs.

Read more →

Chimney Damper Repair

Seized or warped fireplace dampers freed, rebuilt or replaced with a cable-operated unit mounted at the flue top.

Read more →

Chimney Chase Cover

Rusted or sagging metal tops on prefab chimney enclosures replaced with a custom stainless cover that drains instead of ponding.

Read more →
Call (657) 221-6106